2N® EasyGate GSM gateway User Manual Version 1.1.0 www.2n.cz
Changes 1.2 10 1.2 Changes Manual Version Amendments to Earlier Versions 1.00 The User Manual applies to EasyGate FW Version 1.00D. 1.01 New parame
Terms and Symbols Used 1.3 11 1.3 Terms and Symbols Used Manual Symbols Safety Always abide by this information to prevent persons from injury.
13 2 2. Description and Installation This section describes the 2N® EasyGate product and its installation. Here is what you can find in this se
Description 2.1 14 2.1 Description 2N® EasyGate consites of GSM gateway in white plastic cover, removable antenna and cables for connecting to phone
Description 2.1 15 Telephone Line Tones – Operational Tones The GSM gateway sends tones to the telephone line to indicate the line status. The tone f
Description 2.1 16 PUK tone Enter the PUK code. This tone is transmitted upon repeated wrong PIN entering attempts. SIM card is blocked. Te
Before You Start 2.2 17 2.2 Before You Start Product Completeness Check Check the product for completeness before installation please: 1× 2N® Eas
Before You Start 2.2 18 It is impossible to operate EasyGate on sites exposed to direct solar radiation or near heat sources. EasyGate is desig
Mounting 2.3 19 2.3 Mounting External Antenna Connection Screw the antenna enclosed into the SMA antenna connector. Caution Tighten the antenna co
The 2N TELEKOMUNIKACE a.s. joint-stock company is a Czech manufacturer and supplier of telecommunications equipment. The product family develope
Mounting 2.3 20 Wall mounting 2N® EasyGate is equipped with two hangings on the back side for wall mounting. For drilling holes to the wall could be
Telephone line connection 2.4 21 2.4 Telephone line connection PBX Connection Connect 2N® EasyGate to a free CO line of your PBX. Configure your PBX
SMS Sending Input Connection 2.5 22 2.5 SMS Sending Input Connection You have got a special connector for easy connection to EasyGate. The connector
23 3 3. Configuration 2N® EasyGate This section describes configuration of the product 2N® EasyGate. Here is what you can find in this section
2N® EasyGate parameters configuration 3.1 24 3.1 2N® EasyGate parameters configuration PC Connection You have got a serial cable for PC connection. I
2N® EasyGate parameters configuration 3.1 25 To cancel any programming step in the programming mode, press a . Having done so, you can hear the refu
2N® EasyGate parameters configuration 3.1 26 Basic Programming Instructions 1. Run the PCManager and select the language for displaying texts on the
2N® EasyGate parameters configuration 3.1 27 Monitoring Monitoring is active when EasyGate is in operation and registered to the GSM network. If Easy
2N® EasyGate parameters configuration 3.1 28 The hardware version setting must conform to hardware version of connected gateway. There are two hardwa
Table of Parameters 3.2 29 3.2 Table of Parameters All programmable parameters are listed in this section. Each parameter is accompanied with the uni
Table of Contents 1. Product Overview... 71.1 Product Description ...
Table of Parameters 3.2 30 Signaling Line reversal indication for call in progress Function No.: - Select call in progress signaling by telephone l
Table of Parameters 3.2 31 Dial tone - cadence Function No.: - This tone is generated after Off-Hook in case EasyGate is ready to accept di
Table of Parameters 3.2 32 Volumes Transmission volume Function No.: 10 Volume setting for GSM transmission with a 4 dB step. Setting options: 1
Table of Parameters 3.2 33 CLI transmitting Function No.: 19 Set this item to enable/disable identification of a telephone line calling from a G
Table of Parameters 3.2 34 Every table line includes a prefix (of variable length) plus parameters that define EasyGate's behavior in case the b
Table of Parameters 3.2 35 Prefix Function No.: - A prefix identifying the call type (GSM, trunk call, free call, etc.). "Other numbers&
Table of Parameters 3.2 36 Extra tariff Function No.: - Pseudo tariff metering setting (tariff is based on call duration). The Extra tariff par
Table of Parameters 3.2 37 SMS text Function No.: - The SMS text to be sent to the preset telephone number. If the SMS text is blank, an empty
Table of Parameters 3.2 38 Roaming enable/disable Function No.: 42 You can make EasyGate work even if it is registered to a foreign GSM network. S
Table of Parameters 3.2 39 Minimal credit Function No.: - Set minimal credit value to send warning SMS "LOW CREDIT". If credit is lowe
FXS Routing Parameters ... 33FAX/DATA routing parametre
Table of Parameters 3.2 40 COM enable Function No.: 50 With this parameter you can enable/disable the serial interface function. You can disabl
Table of Parameters 3.2 41 Global initialization Function No.: 99 Initialization of all EasyGate parameters including the PIN and service passwor
43 4 4. Function and Use This section describes the basic and extending functions of the product 2N® EasyGate . Here is what you can find in th
Voice function 4.1 44 4.1 Voice function Outgoing and incoming call establishing procedures for an analog telephone are described for illustration. T
Voice function 4.1 45 dialing during the BabyCall timeout cancels this function and a standard outgoing call can be made. Tariff pulses 16 or 12 kHz
Voice function 4.1 46 Call forwarding For forwarding activation you must specify <Telephone number> the calls will be forwarded to. You may spe
Voice function 4.1 47 Call forwarding if no answer If activated, incoming calls will be forwarded to the configured telephone number if incoming call
Voice function 4.1 48 Call waiting If the call waiting is activated the incoming call isn’t refused if there is call in progress on EasyGate. If ther
FAX and Data function 4.2 49 4.2 FAX and Data function Only EasyGate with fax converter supports fax and data functions. Sending fax message or mode
6.1 Regulations and directives ... 626.2 List of Figures
FAX and Data function 4.2 50 DTMF codes for data receive: *9800# Reset of all following settings for data receive *9801# The next call are d
SMS Sending Input 4.3 51 4.3 SMS Sending Input This universal input is intended especially for reporting alarm or error statuses of any equipment pr
COM – Serial Interface 4.4 52 4.4 COM – Serial Interface The complete serial interface RS-232C on a 9-pin connector is identical with any external m
COM – Serial Interface 4.4 53 CSD or High-Speed GPRS Data Connection to Internet To connect to the Internet, install the faxmodem driver from the Eas
COM – Serial Interface 4.4 54 Outgoing and incoming calls can be made during GPRS connection. The GPRS connection remains active during the whole cal
SIM Card PIN protection 4.5 55 4.5 SIM Card PIN protection If a SIM card is PIN-protected and the PIN is not programmed in EasyGate, GSM LED indicat
57 5 5. Technical parameters This section describes the technical parameters of the product 2N® EasyGate .
Technical Parameters 5.1 58 5.1 Technical Parameters GSM Power Supply Telephone interface GSM module, GSM bandwidth MC39i EGSM 900 / GSM 1
Technical Parameters 5.1 59 SMS Sending Input Serial interface Others Loop voltage 48 V DC Loop current max. 40 mA Loop resistance max. 800
61 6 6. Supplementary Information This section describes supplementary information of the product. Here is what you can find in this section:
Regulations and directives 6.1 62 6.1 Regulations and directives 2N® EasyGate conforms to the following directives and regulations: Directive 199
List of Figures 6.2 63 6.2 List of Figures Figure 2.1 2N® EasyGate LED indicators ...
Troubleshooting 6.3 64 6.3 Troubleshooting For tips for the solution of other potential problems see faq.2n.cz. No LED is on after power up Ch
List of Abbreviations 6.4 65 6.4 List of Abbreviations APN Access Point Name – necessary for the GPRS service CLIP Calling Line Identification
List of Abbreviations 6.4 66 SIM Subscriber Identity Module - a chip-equipped module to be inserted in a GSM device for identification SMS Shor
General Instructions and Cautions 6.5 67 6.5 General Instructions and Cautions Please read this User Manual carefully before using the product. Foll
General Instructions and Cautions 6.5 68 Electric Waste and Used Battery Pack Handling Do not place used electric devices and battery packs into
2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Prague 4, Czech Republic Tel.: +420 261 301 500, Fax: +420 261 301 599 E-mail: [email protected] Web: www
7 1 1. Product Overview In this section, we introduce the2N® EasyGate product, outline its application options and highlight the advantages foll
Product Description 1.1 8 1.1 Product Description Basic Features The primary purpose of EasyGate is to transmit voice between a GSM network and an
Product Description 1.1 9 Safety Precautions Do not switch on 2N® EasyGate in the vicinity of medical apparatuses to avoid interference. The minimum
Kommentare zu diesen Handbüchern