4
Maxstar
®
280 Control Panel
DC TIG (HF Start)
1. Tungsten Size = .020 –1/8 in. or .05 – 3.2 mm
2. Remote Trigger = STD/HOLD/OUTPUT ON
DC TIG (Lift-Arc)
1. Tungsten Size = .020 –1/8 in. or .05 – 3.2 mm
2. Remote Trigger = STD/HOLD/OUTPUT ON
DC Stick (Schedule 1 and 2)
1. Hot Start = ON/OFF
2. Remote Trigger = OUTPUT ON/HOLD/STD
1. Arc Time 0.0 – 9999 hours
0.0 – 59 minutes
0 – 999,999 cycles
Resettable
2. Error Log = Error event recorder
3. Sleep Timer = 1/5/10/15/30/45MIN/1HR
4. Stick Stuc = OFF/ON
5. OCV = LOW/NORM
6. Cooler Power = AUTO/OFF (only on Maxstar models with CPS )
7. Machine Reset
8. Software Number
9. Serial Number
User Menu (Hold Menu button three seconds.)
Tech Menu (Hold Menu button five seconds.)
1. Standby Switch
2. Voltmeter Display
3. Ammeter Display
4. Output Contactor “On” Indicator
5. DC TIG (HF Start) Process Menu Parameters
Amperage 1–280 A**
Pulse* Off – 250 PPS
Postflow Auto/Off – 50 seconds
6. DC Stick (Schedule 1) Process Menu Parameters
Amperage 5 – 280 A
DIG* Off –100%
7. Memory Card Port
8. Activity Indicator
9. Encoder Control
10. Menu Ranges
11. DC TIG (Lift-Arc) Process Menu Parameters
Amperage 1 – 280 A**
Pulse* Off – 250 PPS
Postflow Auto/Off – 50 seconds
12. DC Stick (Schedule 2) Process Menu Parameters
Amperage 5 – 280 A
DIG* Off –100%
13. Process Selector
*Pro-Set parameter selectable. **Amperage range is tungsten size dependent.